Apparatus and reagents required:
- Solution of 0.05% of nonionic interfacial active agent
- Beaker
- Supporting frame of horizontal bar
Specimen preparation:
- For testing print or stripe patterned fabrics, cut a test specimen in 2, 5 cm width and in length more than 20 cm (stripes should be horizontal).
- For testing solid colour fabrics, cut a test specimen in width 2, 5 cm and 3 cm in length out of the fabric. Use an undyed cotton cloth (JIS cloth) in width 2, 5 cm and in length more than 20 cm and sew it together with the test specimen at the short side.
Procedure:
- Test conducted under standard condition (20 ± 2°C, 65 ± 2 % RH). Air flow must be avoided.
- Pour 50 ml or 100 ml of the 0, 05% non-ionic surface active agent into a beaker.
- Immerse one end of the test specimen into the beaker so that approx. 2 cm is dipped into the solution.
- The same test as above must be done with a blank specimen by using a separated bath.
- Remove the specimen after 2 hours.
- Dry it by hanging at room temperature.
- Tested specimen and blank test specimen shall be returned to the applicant.
Evaluation:
How can i get a 0, 05% non-ionic surface active agent?
ReplyDelete